Every year the Clean Energy Regulator (CER) sends independent inspectors to a random sample of solar systems installed under the Small-scale Renewable Energy Scheme. For 2025–26, it inspected solar batteries for the first time, after batteries became eligible under the scheme on 1 July 2025. The CER published the results on 13 November 2026.
The findings are worth knowing about if you own solar or a solar-connected battery, especially one installed in the last couple of years. Here's what the report found, what the ratings mean, and some calm, practical steps you can take.
Source: Clean Energy Regulator, 2025–26 SRES inspection report highlights (last updated 13 November 2026) and the full 2025–26 inspection report. All figures below are quoted as published.
The headline results
Solar batteries. The CER completed 3,425 solar battery inspections in the program's first year, covering systems installed from 1 July 2025 to 30 April 2026. Of the 3,373 randomly selected inspections:
- 37.86% were adequate
- 61.19% were substandard
- 0.95% were unsafe
Solar panel (PV) systems. The CER inspected 3,129 randomly selected solar PV systems installed between 1 July 2024 and 30 April 2026:
- 75.97% were adequate
- 23.11% were substandard
- 0.93% were unsafe
The CER reports that the battery substandard rate "peaked at 68.3% in August 2025" and has "since dropped to 54.9% for systems installed in April 2026", after it stepped up education and compliance activity.
In Victoria, the report's appendices list 678 randomly selected battery inspections, with 385 rated substandard and 4 unsafe. For solar PV, they list 666 inspections, with 65 substandard and 3 unsafe.
What "substandard" and "unsafe" actually mean
The ratings sound alarming, so it helps to read the CER's own definitions:
- Adequate: the installation meets the required standards.
- Substandard: the system "is safe to remain in operation, but the installation may not meet one or more clauses in the Australian standards. This doesn't mean the whole system is non-compliant. In most cases, it isn't an immediate cause for concern but could be an issue later."
- Unsafe: the installation "is not safe to remain in operation and is shut down immediately or otherwise made safe by the inspector."
So a substandard rating usually means something needs fixing to meet the standards, not that the system is dangerous today. Unsafe results were rare, at under 1% for both batteries and solar PV. Some unsafe ratings weren't caused by the installer at all. Of the 32 unsafe batteries, the CER attributes 8 to a product recall and 1 to a third-party incident. Of the 29 unsafe solar PV systems, 12 were due to third-party incidents, such as weather damage or structural changes to the building, and 1 to a product recall.
The most common problems found
On solar batteries, the most common reasons for a substandard rating were:
- Labelling: missing or incorrect critical warning labels, and backup circuits not clearly identified. The CER says early inspection results identified labelling as the most common cause of substandard outcomes.
- Wiring: a residual current device (RCD) that's incorrectly configured or missing when the system has an alternate supply.
- Overcurrent protection: circuit protection that isn't adequately rated.
- Mechanical protection: not enough physical protection for cables and the battery.
The main causes of unsafe battery ratings included neutral continuity not being maintained for circuits running on an alternative supply, and loose connections in associated wiring showing signs of heat.
On solar panel systems, the most common rectification categories were:
- Cable and conduit: cables not meeting size or protection requirements, poorly fixed, or conduit not routed correctly.
- Earthing: improper bonding or earthing of panel frames and equipment.
- DC connectors: solar connectors that aren't compatible, secure or correctly installed.
- Mounting structure: rails, clamps and frameworks not sufficiently installed.
- System design and configuration not meeting the relevant standards.
Common causes of unsafe solar PV ratings were cabling with exposed live parts, and earthing lugs installed incorrectly so that they penetrate the panel backing sheet.
What the regulator is doing about it
Installers whose work is rated substandard or unsafe must return to site, fix the issues and give proof to Solar Accreditation Australia (SAA). Since 1 July 2025, the CER says it has issued 716 initial advisory letters, 121 warning letters and 1 notice of intent to suspend an installer from the scheme. From 1 March 2026 it also made photographs of critical battery labels mandatory evidence.
What this means for you
Only a sample of systems is inspected, so most owners won't have had a CER inspection. A few sensible steps:
- Don't panic. Substandard usually means "fix this to meet the standard", not "dangerous now". Unsafe results were under 1%.
- If you were inspected, the installer is responsible for returning to rectify the issues identified. Keep the paperwork.
- Look, don't touch. From the ground and without opening anything, you can check whether there are warning labels and a shutdown procedure sign near your inverter, battery and switchboard. Don't remove covers or go onto the roof.
- Watch for warning signs: a burning smell, heat marks, buzzing, damaged cabling, or repeated fault messages on the inverter or battery. If you see these, keep clear and call a licensed electrician. Call 000 in an emergency.
- If your installer can't be reached, or you'd like an independent check, a licensed and accredited service business can look over the accessible parts of your system.
How Solar and Battery Dr can help
We service and repair existing solar and solar-connected battery systems across Melbourne. We don't sell new installations. We fix solar. We don't sell it.
- Battery servicing for solar-connected batteries of all brands, including discussing replacement of an existing battery when that's the right step.
- Solar repairs and fault finding when something has changed or a fault has appeared.
- A Solar System Health Check covering agreed, accessible parts of the system: rooftop panels, switches, cracked tiles and cabling; inverter performance testing; and switchboard switches.
- Monitoring and app repairs when your solar or battery app stops updating.
Solar and Battery Dr is licensed and insured, REC 35318, and CEC and SAA accredited.
Want your system looked at? Call 1300 353 224 or make an enquiry. An enquiry is not a confirmed booking; we discuss your system and the next step with you.
Frequently asked
questions.
Does "substandard" mean my system is dangerous?
Not usually. The Clean Energy Regulator says a substandard system is safe to remain in operation, but may not meet one or more clauses of the Australian standards, and in most cases isn't an immediate cause for concern.
What were the most common battery installation problems?
Labelling (missing or incorrect warning labels and backup circuits not identified), wiring (RCD configuration with alternate supply), overcurrent protection and mechanical protection, according to the CER's 2025–26 report.
Who fixes problems found in a CER inspection?
Where an inspection is rated substandard or unsafe because of the installation work, the installer must return to site to rectify the issues and provide proof to Solar Accreditation Australia.
Can I check my own system?
Only from a safe position. Look for warning labels and a shutdown procedure sign, and watch for burning smells, heat marks or repeated faults. Don't open equipment or go onto the roof.
Do you service batteries you didn't install?
Yes. We service solar-connected batteries of all brands that are already installed. We don't sell new battery installations.
Solar not working?Call us today.
1300 353 224Want your system looked at? To talk about an existing solar or battery system in Melbourne, call 1300 353 224, or make an enquiry.
Hours: Monday to Friday 7:00am to 5:30pm. Saturday 8:00am to 3:30pm.